Officer Incharge : Shri A V R Subba Rao
Supervisor Incharge: Shri P N Nagaraju
Description: |
---|
The outdoor mechanical lab has the following installations: - Mechanical Lever Frames : Double wire (48 lever), Direct Type Lever (12 levers), Catch Handle Type Lever Frames.
- Std -III 3 line BG layout –Double wire operated MAUQ signalling , Distant signal motor operated, points are operated by wire mechanisms/rodding/SLM.
- 2-line MG layout with STD-I interlocking, LQ with mechanical disengager operated by direct LF SA530, points locally operated, points secured by HP locks.
- A swing type LC gate is located between outer and home on one side.
- Diamond crossing with 12 LF direct lever frame with shunt signals and detection by unit wise detector.
- 2-line BG layout LQ for demonstrating the inter-cabin slotting circuit with two end-cabins 16 lever frame with goomty for slide frame.
- Lifting Barrier Type LC gates.
|